| J405-0008
Jerome 405 Mercury Vapour Analyser with Comms |

|
The Jerome® J405 portable mercury vapour monitor is redefining the portable mercury vapour analyzer market. Significant performance enhancements and modern communications capabilities have been combined to create a new option for mercury spill detection and clean-up analysis. Like its 411 & 431X predecessors, the J405 utilizes the industry-proven, inherently stable and reliable gold film sensor technology and simple, one-button operation.
The larger display, on-board data logging,
auto zeroing, and battery-powered sensor regeneration will simplify
operation and maintenance in the field. Menu-driven programming and SCADA
compatibility via 4-20 ma output further enhance data retrieval, storage
and reporting.
* USB data communications on the J405 - 0008
only
|
| Applications |
- Mercury spill response & cleanup
- Facility Monitoring
- Hazardous Waste Sites
- Worker Safety
- Landfill Monitoring
|
- Mercury Exclusion Testing
- Source Surveys
- Fluorescent Lamps Disposal & Recycling
- Exhaust Duct Monitoring
|
|
| J405
Features |
- Detection limit down to 0.5 µg/m3
- Meets EPA & ATSDR cleanup level protocols
- Longer sensor life
- Battery powered sensor regeneration
- On-board data logging (20,000 data points)
- Auto time/date stamp
- USB data output
- SCADA interface capabilities via 4-20ma
|
|
| Optional
Accessories |
- Car Adapter
- Dosimeter Analysis Kit
- External Battery Pack
- Functional Test Kit
- Maintenance Kit
|
|
| Specifications |
| Resolution |
0.013 µg/m3 |
| Detection Range |
0.5-999 µg/m3 |
| Precision |
15% RSD @ 1µg/m3 |
| Accuracy |
± 10% @ 1 µg/m3 |
| Response Time |
12 s |
| Flow Rate |
750 cc/min |
| Environmental Range |
0-40° C, non-condensing, non-explosive |
| Interfaces |
USB host, USB slave |
| Dimensions |
11" L x 6" W x 6.5" H/ 28 cm L x 16 cm W x 17 cm H |
| Weight |
5.3 lbs/ 2.4 kg |
| Internal Battery Pack |
Rechargeable nickel-metal-hydride |
| Power Requirements |
12V DC/Power Adapter |
| Warranty |
One year, factory parts and labour |
| Certifications |
UL (pending), CE |
|
|
Technical Notes:-
This instrument should not be allowed to ingest
liquids as these can cause serious damage, especially to the sensor. Sensor
regeneration* should be performed at the start of a day’s monitoring
and again at the end. Sensor regeneration should be performed at an interval
of no more than 30 days.(mains power required). A clean power source 220-240V
50/60Hz is required.
Quantity:
£9,010.00 
Delivery: Typically 4 weeks |
| Please select product options:- |
|
|
|